Limited testing has been performed on the following Summagraphics tablets. All tablets listed were found to be operational with a 4-button cursor in Windows 3.x/95/NT.

MM1201
MM1201+
MM1812
MM1812+
MMLC961
HIPAD+9012 (see below)

Although many of these tablets will function properly with the TabletWorks 5.2 driver set, due to the numerous firmware revisions and the lack of inventory of these products, compatibility cannot be guaranteed with every tablet. If your tablet does not function with the TabletWorks 5.2 driver set, we invite you to contact Summagraphics Sales for new product information.


HIPAD+ 9012 Settings for the TabletWorks 5.2 Driver Set

Tablet configuration

1. Set the tablet to Menu Mode.
2. Select the following settings on the tablet menu:

Tablet Selection Summasketch
Baud Rate 9600
Word Length 8 Data Bits
Origin Location Lower Left Origin
Primary Mode Stream (Run)
Mode Modifier Incremental
Incremental Limit 1 Count
Tablet Resolution 1000 Lines/Inch (lpi)
Report Rate 100 Coordinates/Second

3. Save the tablet settings.
4. Turn the tablet off.
5. Install the TabletWorks 5.2 driver.
6. Select "SummaSketch (MM only)" as the tablet type.
7. Turn on the tablet "AFTER" the computer is restarted.

Note: The HIPAD+ 9012 tablet must be turned off until the computer is fully booted to ensure proper operation. If the tablet is turned on prior to this, the tablet will fail to function.





 