Home Resellers
  Digitizing & Measurement Products   
Technical Support > CalComp Knowledge Base or Summagraphics Knowledge Base

Knowledge Base  

Prepare Microgrid Ultra for Use in Windows 3.x/95/NT

Verify the DIP switch settings are set correctly.

    The DIP switches for this tablet are located on the back of the unit enclosed in the metal controller panel.  There are
    three banks of eight switches labelled 1, 2, and 3.

    1.  The DIP switch settings should be set as follows:

  ______________________________________________
  SET 1               1-1    1-2   1-3   1-4   1-5   1-6    1-7   1-8
  --------------------------------------------------------------------------------
  Baud:9600          ON     OFF   OFF   ---   ---   ---    ---   ---
  Parity:Enabled     ---   ---   ---    ---   ON    ---   ---   ---
        :Even         ---   ---   ---    ON    ---   ---   ---   ---
  Stop Bits:2        ---   ---    ---   ---   ---   ON    ---    ---
  Data Bits:7        ---   ---    ---   ---   ---   ---   OFF    ---
  Rpt Format:Binary  ---   ---   ---   ---    ---   ---   ---   OFF

  ______________________________________________
  SET 2               2-1    2-2   2-3   2-4   2-5   2-6    2-7   2-8
  --------------------------------------------------------------------------------
  Resolution:English ---   ---   ---   OFF    ---   ---   ---   ---
  Resolution:1000LPI ---   ---   ---   ---    OFF   ON    ---   ---
  ASCII Fmt:Counts   ON    ---   ---    ---   ---   ---   ---   ---
  ASCII Termntr:CR   ---   ---   OFF   ---    ---   ---   ---   ---
  ASCII Decml Pnt:Ex ---   OFF   ---   ---    ---   ---   ---   ---
  Format Emul:UIOF   ---   ---   ---   ---    ---   ---   OFF   OFF

  _______________________________________________
  SET 3               3-1    3-2   3-3   3-4   3-5   3-6    3-7   3-8
  ----------------------------------------------------------------------------------
  Report Mode:Stream ON    ON    ---   ---    ---   ---   ---   ---
  Echo:Off           ---    ---   OFF   ---   ---   ---    ---   ---
  Prox Xmit:In-prox  ---   ---   ---   OFF    ---   ---   ---   ---
  Margin Xmit:Active ---   ---   ---   ---    OFF   ---   ---   ---
  Dual Trans:Disable ---   ---   ---   ---    ---   OFF   ---   ---
  Trans Select:Cursor---   ---   ---   ---    ---   ---   ON    ---
  Customized Option  ---   ---   ---   ---    ---   ---   ---   OFF

    2.  The outside frame that houses the DIP switches has a "1" marked on the top side of the DIP switches and a "0"
         on the lower side.

        To change a switch setting to ON, depress the side of the switch toward the number "1".

        To change a switch setting to OFF, depress the side of the switch toward the number "0".
 
        (Use a small screwdriver to depress the switch.   Do not use a lead pencil or other instrument that may damage
        or mark the switch).



 
© GTCO CalComp, Inc.                                                                                          Site Map  |  Legal Information  |  Web Site Comments Only